[Home] [Catalog] [Category] [Previous Item] [Next Item]

MC Products

How to Specify

[Item Image] Series 4000 Overheat Indicators
How to Specify for Pump & PTO
An MC Product Series 4000 overheat indicator shall be supplied, consisting of a
thermostat that is to be mounted to the pump housing and a display module to be
mounted to the pump panel.

The control wires connecting the control module to the thermostat shall consist of (2)
#18 gauge wires bonded and 2 female connectors.

Sensing device shall be a sealed Bimetallic Disc Thermostat encased in metallic
casing with a fixed stainless steel bracket and 2 male connections. The thermostat
shall activate at 125 degrees Fahrenheit (+ or - 5 degree variance).

Display module on pump panel will have flashing incandescent lamps with colored
lenses for superior visibility in direct sunlight. The test switch can be used to test
the alarm and light portion of the unit.



MC Products

P.O Box 821
Holbrook NY 11741-0821
Telephone: 1 (800) 843-6465
Fax: 1 (800) 582-5319
E-Mail: customerservice@mcproducts.com